Micro Gate ?GRAPH Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Flutlichter Micro Gate ?GRAPH herunter. Micro Gate ?GRAPH User manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - User Manual

User Manual Manual Version 1.2 Software Version 1.4

Seite 2 - Contents

Microgate Srl P. 10 / 74 To look for a particular athlete or to filter data (e.g. to search for all athletes beginning with “Ross”), type the

Seite 3

Microgate Srl P. 11 / 74 Associating each athlete with a photograph is quite useful, especially for trainers and coaches who have a large num

Seite 4 - 1 GENERAL OVERVIEW

Microgate Srl P. 12 / 74 3.1.1.1 ATHLETE INFORMATION FORM To edit an athlete's information, use your mouse to select a row on the grid an

Seite 5 - 1.5 UTILITIES

Microgate Srl P. 13 / 74 3.1.2.1 CREATION OF A NEW START LIST Click on <New>, name the list and choose the athletes that will be a part

Seite 6 - 2 SOFTWARE INSTALLATION

Microgate Srl P. 14 / 74 The <Group> button allows you to choose athletes that belong to one or more groups (if we have already created t

Seite 7

Microgate Srl P. 15 / 74 3.1.3 INSERT / MODIFY GROUP In this section infinite groups and subgroups can be created, making it easy to manage the

Seite 8 - ESCRIPTION OF THE FUNCTIONS

Microgate Srl P. 16 / 74 To add one or more athletes to a group, you have a variety of options: 1) Select the group to which you want to add a

Seite 9 - 3.1 ATHLETES

Microgate Srl P. 17 / 74 With <Remove from Group> the athlete selected in the grid is removed; the athlete is only removed but not elimin

Seite 10

Microgate Srl P. 18 / 74 3.1.4 RFID TAG MANAGEMENT Witty·RFID is an automatic athlete detection system that makes the trainer's work easie

Seite 11

Microgate Srl P. 19 / 74 There are two ways for writing an RFID tag:  Select the athlete to whom the bracelet should be assigned from the ath

Seite 12 - 3.1.2 START LISTS

Microgate Srl P. 2 / 74 Contents 1 General Overview ...

Seite 13 - REATION OF A NEW START LIST

Microgate Srl P. 20 / 74 The workflow just described is very efficient if there is a registry of athlete already entered; if instead the datab

Seite 14

Microgate Srl P. 21 / 74 What is not checked is if the bib numbers entered in the database or written on the tags are unique. The user is respo

Seite 15 - 3.1.3 INSERT / MODIFY GROUP

Microgate Srl P. 22 / 74 3.2 TESTS In this section it is possible to create and manage various customized test types as well as different resu

Seite 16 - SHIFT , click on “Fierro”

Microgate Srl P. 23 / 74 The drop-down menu of the Template field shows the default base template, as well as all other templates created by t

Seite 17

Microgate Srl P. 24 / 74 3.2.2 DEFINE / MODIFY GRID CONFIGURATION This function is used to create templates for viewing results imported from t

Seite 18 - 3.1.4 RFID TAG MANAGEMENT

Microgate Srl P. 25 / 74 Adding the columns, the grid is populated with example data and relevant graphs. In some cases (Lap, Split, Lap Spee

Seite 19

Microgate Srl P. 26 / 74 If columns have already been added and a new one has to be added between two columns, proceed as follows: select the c

Seite 20

Microgate Srl P. 27 / 74 Graphs can be configured so as to be displayed, set the display type (lines or bars), and their color.  Click on

Seite 21

Microgate Srl P. 28 / 74 For intermediate times, please remember the difference between LAP and SPLIT: SPLIT is the running time beginning fro

Seite 22 - 3.2 TESTS

Microgate Srl P. 29 / 74 3.2.3 AVAILABLE COUNTDOWN TEMPLATES When the Witty SEM option is activated in the Basic, MultiStart, Counter tests in

Seite 23

Microgate Srl P. 3 / 74 3.3.3 Numerical Data Table ...

Seite 24

Microgate Srl P. 30 / 74 5 4 3 2 1 ▓ ▓ ▓ ▓ ▓

Seite 25

Microgate Srl P. 31 / 74 3.2.4 DEFINE/CHANGE TEMPLATE SEQUENCES For the Witty·SEM / Agility tests, it is possible to define a personalised sequ

Seite 26

Microgate Srl P. 32 / 74 The tools are: Add Witty·SEM Add Start Add passage and arrival points Select object Move object Insert direct connec

Seite 27

Microgate Srl P. 33 / 74 The basic concept is to represent the route to be completed by the athlete on the screen, indicating which traffic lig

Seite 28 - START STOPL1 L2 L3

Microgate Srl P. 34 / 74 Proceed with a second connection, i.e. from A to B Using the square, it is possible to indicate not the di

Seite 29

Microgate Srl P. 35 / 74

Seite 30 - 5 4 3 2 1 ▓ ▓ ▓ ▓ ▓

Microgate Srl P. 36 / 74 Using the Arrow instrument (Selection) it is possible to enter the distances simply by clicking on the

Seite 31

Microgate Srl P. 37 / 74 It is also possible to create a route where the athlete returns from one point to another one, by clicking again on th

Seite 32

Microgate Srl P. 38 / 74 Again using the arrow tool (select), click on a previously positioned Witty·SEM to change the traffic light address.

Seite 33 - ONNECTIONS AND DISTANCES

Microgate Srl P. 39 / 74 3.2.4.3 ELEMENT REMOVAL With the removal tool, it is possible to delete elements or connections. Click what you want

Seite 34

Microgate Srl P. 4 / 74 1 GENERAL OVERVIEW Witty Manager is the Witty Timer Kit's management software. It can be used to create athletes&

Seite 35

Microgate Srl P. 40 / 74 3.2.4.4 REPETITIONS It is possible to use the drop down menu at the bottom of the toolbar to indicate how many times

Seite 36

Microgate Srl P. 41 / 74 3.3 RESULTS In the Results section the tests (trials) performed are displayed. The RESULTS window is divided into 3 pa

Seite 37

Microgate Srl P. 42 / 74 Filters Panel To look for an athlete or test, the data can be inserted manually into the search boxes (e.g. key in “Ro

Seite 38

Microgate Srl P. 43 / 74 Test List Click on the column names (Test, Data) to order the list according to that field. Press again to reverse th

Seite 39 - 3.2.4.3 ELEMENT REMOVAL

Microgate Srl P. 44 / 74 Test Analysis To view a single test, double-click on the corresponding line in the 'TEST ANALYSIS' table. To

Seite 40 - 3.2.4.4 REPETITIONS

Microgate Srl P. 45 / 74 Whereas by pressing <Show> when multiple tests are displayed in the list, the sum of the results of the N tests

Seite 41 - 3.3 RESULTS

Microgate Srl P. 46 / 74 The screen can be devided into three large areas:  left configuration panel  graphs  numerical data grid 3.3.1

Seite 42 - Filters Panel

Microgate Srl P. 47 / 74 3.3.1.1.1 Configure columns Using the <Configure columns> command a template different from the default templat

Seite 43 - Test List

Microgate Srl P. 48 / 74 3.3.1.1.2 Configure Speed Multi Base Similar to the Test Definition procedure, it is possible to view (and modify) po

Seite 44 - Test Analysis

Microgate Srl P. 49 / 74 Please refer to the Witty Timer Kit manual for a detailed explanation of concepts such as Speed Bases (chap. 5.1.1.4.3

Seite 45

Microgate Srl P. 5 / 74 1.3 RESULTS In this section the results of previously performed tests can be viewed. The results can be filtered by at

Seite 46 - 3.3.1.1 CONFIGURE

Microgate Srl P. 50 / 74 3.3.1.2 SORT BY This allows to choose the order for viewing (numerical and graphic) data, i.e. which columns to sort

Seite 47

Microgate Srl P. 51 / 74 3.3.1.3 FILTER The 'Filter' command allows to filter the numerical grid lines using two fields: - the ath

Seite 48

Microgate Srl P. 52 / 74 3.3.1.4 PRINT Pressing <Print> in the 'Show' window will create a highly configurable report. The ra

Seite 49

Microgate Srl P. 53 / 74 The other toolbar commands are:  Apply: Has the same function as <Apply> when modifying the visibility of a s

Seite 50 - 3.3.1.2 SORT BY

Microgate Srl P. 54 / 74 3.3.2 GRAPHS All numerical value columns represented in the applied template (times, intermediate times, gaps, speeds)

Seite 51 - 3.3.1.3 FILTER

Microgate Srl P. 55 / 74 3.3.3 NUMERICAL DATA TABLE As explained above, the numerical data grid displays the single lines depending on the appl

Seite 52 - 3.3.1.4 PRINT

Microgate Srl P. 56 / 74 3.4 WITTY In this section, once the Witty timer is connected to the PC, various functions can be managed; verify the d

Seite 53

Microgate Srl P. 57 / 74 3.4.2 UPLOAD DATA TO WITTY This option uploads data from the PC to the Witty timer, such as customized test definition

Seite 54 - 3.3.2 GRAPHS

Microgate Srl P. 58 / 74 3.4.3 DOWNLOAD DATA FROM WITTY This option allows to download test data from the Witty timer to the PC. If the test ty

Seite 55 - 3.3.3 NUMERICAL DATA TABLE

Microgate Srl P. 59 / 74 NB: If the tests have been timed when the athletes' names were not present on the Witty, and the athletes's

Seite 56 - 3.4 WITTY

Microgate Srl P. 6 / 74 2 SOFTWARE INSTALLATION Download the WittyManager.exe setup file from your flash drive or from our website and launch

Seite 57 - 3.4.2 UPLOAD DATA TO WITTY

Microgate Srl P. 60 / 74 If the database contains more than one athlete with the same bib, when transferring the tests, the user is asked which

Seite 58

Microgate Srl P. 61 / 74 3.4.5 WITTY PHOTOCELL FIRMWARE UPDATE Similarly to the timer, it is also possible to update the photocell firmware. Co

Seite 59

Microgate Srl P. 62 / 74 3.4.6 CONFIGURE WITTY PHOTOCELL This function allows to change some settings of a photocell which is connected via USB

Seite 60 - 3.4.4 WITTY FIRMWARE UPDATE

Microgate Srl P. 63 / 74 3.4.6.2 ACTIVATION This particular setting (which can be changed ONLY from the Witty Manager and not from the timer,

Seite 61

Microgate Srl P. 64 / 74 3.4.6.2.3 Active After Waiting Time This configuration allows to set the photocell as "normally closed" for

Seite 62

Microgate Srl P. 65 / 74 3.4.7 CONFIGURE WITTY·RFID This process is similar to configuring the photocells (chap. 3.4.5). Put Witty·RFID in conf

Seite 63 - 3,2,1…GO!

Microgate Srl P. 66 / 74 3.4.11 WITTY TAB FIRMWARE UPDATE This function is similar to the update for the photocell firmware (chap. 3.4.6). Conn

Seite 64

Microgate Srl P. 67 / 74 3.5 UTILITY 3.5.1 BASIC SETTINGS Allows to change the following settings. Please remember to press <Save> before

Seite 65 - 3.4.9 CONFIGURE WITTY·SEM

Microgate Srl P. 68 / 74 3.5.2 DATABASE Witty Manager manages all data (athletes, tests, results, settings, etc.) in a database file (Sql Serve

Seite 66

Microgate Srl P. 69 / 74 3.5.2.1 DATABASE This is the directory where the database used at the moment is stored; use the commands <New>

Seite 67 - 3.5 UTILITY

Microgate Srl P. 7 / 74 If you want everyone with access to the computer to be able to use the product, select “Everyone”, otherwise select “Ju

Seite 68 - 3.5.2 DATABASE

Microgate Srl P. 70 / 74 3.5.2.6 IMPORT Imports a .wyt file previously exported to another PC or to the same PC if data have been deleted or r

Seite 69 - 3.5.2.5 EXPORT AND SAVE AS

Microgate Srl P. 71 / 74 3.5.3 CHECK UPDATE When this button is pressed, the system will check if the installed version is the most recent one.

Seite 70 - 3.5.2.6 IMPORT

Microgate Srl P. 72 / 74 3.6 HELP Loads this PDF file. 3.7 QUIT Closes the program.

Seite 71 - 3.5.5 ABOUT

Microgate Srl P. 73 / 74 4 PC MINIMUM REQUIREMENTS A 'regular' desktop or notebook PC with Microsoft Windows Vista Sp2, Windows 7, o

Seite 72 - 3.7 QUIT

Microgate Srl P. 74 / 74 Copyright Copyright © 2009-2015 by Microgate S.r.l. All rights reserved No part of this document or of any of the ind

Seite 73 - 4 PC MINIMUM REQUIREMENTS

Microgate Srl P. 8 / 74 3 DESCRIPTION OF THE FUNCTIONS This chapter details all of the functions of each menu of the Witty Manager program, st

Seite 74 - Microgate S.r.l

Microgate Srl P. 9 / 74 3.1 ATHLETES 3.1.1 INSERT / MODIFY ATHLETES In this section all the athletes stored are displayed. Choose "So

Kommentare zu diesen Handbüchern

Keine Kommentare